Procurement of 1344-1940JHWZ0008 Gas Chromatograph purchasing of Jilin Petrochemical Company Testing Center(1)

2019-06-26
【Buy Bidding Documents】
Clarify or change:Modification of key technical terms and scope of supply
Jilin Chemical Industries Import and Export Company Limited entrusted by the purchaser, invites sealed bids from eligible suppliers home and abroad for the supply of the following goods and/or service by way of International Competitive Bidding. The tender notice was released on www.chinabidding.com on2019-06-26
1、Bidding Conditions
Overview:Name of Project:Gas Chromatograph
Quantity : 4 Sets
The introduction of the bidding project: Cooperate with Jilin Petrochemical Company to carry out various sampling inspection work, as well as the Research Institute's raw material inspection, scientific research and analysis for PMMA and EPDM, etc.

Source of Funds:Funds secured
Description of The Prepared Bidding Conditions:Funds secured
2、Bidding Content
Bidding No:1344-1940JHWZ0008
Project Name:Gas Chromatograph purchasing of Jilin Petrochemical Company Testing Center
Place of Implementation:Jilin city, Jilin province
List of Products:
NO. Product Name Quantity Main Technical DataRemarks
1 Gas chromatograph 1 Set 1. Structure (1) The seven-inch capacitive touch screen interface can provide real-time access to instrument status, configuration and flow path information; a browser interface can be used to remotely control the instrument through the chromatographic IP address, and the browser interface can provide an interface for intelligent mobile access functions. (2) With extended configuration function, it can simultaneously install and operate up to two injection ports and four detectors, six chromatographic column ID ports and three USB ports. (3) Overall performance of system: retention time reproducibility < 0.008% or < 0.0008 minutes; Peak area reproducibility < 0.55% RSD; Integral gas circuit passivation. 2. Column oven: (1) Operating temperature: above room temperature 4 ° C to 450 ° C; (2) Precision of temperature setting: 0.1 ° C. (3) Maximum heating rate: 100 ° C/min. (4) Step of temperature programming: 20 step temperature gradient of the column oven and 21 constant temperature platforms shall be supported. The rate of temperature fall can be set; (5) Temperature fluctuations: environment temperature change 1 ℃, the column oven temperature change < 0.01 ℃; (6) Reproducibility of temperature programming: 1%. 3. Heating area: (1) independent heating area, no column oven: 8; (2) Maximum operating temperature of the auxiliary heating area: 400 ° C; (3) To support up to 10 valves; 4. Electronic gas circuit control: (1) modular electronic air circuit control channel, including all flow and pressure control of injection port, detector or auxiliary air circuit, and equipped with anti-particle pollution device; (2) Pressure setting accuracy: 0.003 psi, the atmospheric pressure sensor compensates for changes in height and ambient temperature; (3) Programmed lift pressure/flow: 3 steps; (4) With a variety of electronic gas circuit control and operation mode: constant current, constant pressure, programmed lift of flow and pressure, pulse pressure; (5) Accuracy of flow sensor: < ±5% 5. Detector: four detectors can be installed and operated at the same time. It is applicable to electronic gas circuit control and electronic on/off of all detector gases. The atmospheric pressure sensor compensates for changes in height and ambient temperature. (1) Flame ionization detector with electronic gas circuit control; maximum operating temperature 450° C; the minimum detection limit: < 1.2 pg C/s calculates the linear dynamic range by n-tridecane > 107, and the whole-process digital data path can conduct quantitative analysis of the peak within the whole concentration range of 107 in a single operation. Maximum data collection rate: up to 900 Hz, and provide relevant certificates; flameout detection and automatic reignition. (2) Thermal conductivity detector with electronic gas circuit control: universal detector with minimum detection limit for all compounds except carrier gas: 400 pg tridecane /mL, using He as carrier gas; Linear dynamic range: > 105 5%; the unique fluid switching design provides fast, stable and low drift performance. The design of single wire microcell has better sensitivity and reproducibility, cell volume: 4ul; the highest temperature: 400 ° C. 6. Shunt/non-shunt capillary injection port with electronic gas circuit control (1) Electronic pressure/flow control (including carrier gas, fuel gas and auxiliary gas); (2) Sealing system of plate-rotating top cover inject port, convenient for maintenance and disassembly; (3) Diagnosis including leakage/current limiting, pressure attenuation and current limiting test at the shunt outlet (nut removal pad purge and shunt outlet); (4) Maximum operating temperature: 400 ℃. (5) Pressure range: 0-1032kpa; (6) Maximum shunt ratio: 7500:1; (7) Setting range of total flow: 500ml /min N2 7. Packed column injection port with electronic gas circuit control :(1) directly inject the sample to the filling and wide-diameter capillary column; (2) Electronic flow/pressure control: 0 -- 100 psig pressure range, 0.0 -- 200.0 mL/min flow range; (3) Select the range to obtain the best performance over the set value range of conventional packed column; (4) Electronic spacer purge flow control; (5) Maximum operating temperature of 400 ° c. adapted connector can be used to 1/8 of an inch packed column and capillary column is 0.530 mm. 8. Automatic sampler :(1) more than 17 bits; (2) Sample size range: 0.1~50ul; (3) Linear injection quantity: 99% 9. Workstation: software: WINDOWS 10 Chinese operating system, Chinese intelligent software and retention time locking software. Chromatographic software with personalized processing for data processing, equipment control, data analysis and automatic control.
2 Gas chromatograph 1 Set 1. Structure (1) The seven-inch capacitive touch screen interface can provide real-time access to instrument status, configuration and flow path information; (2) a browser interface can be used to remotely control the instrument through the chromatographic IP address, and the browser interface can provide an interface for intelligent mobile access functions. (3) with extended configuration function, it can simultaneously install and operate up to two injection ports and four detectors, six chromatographic column ID ports and three USB ports; (4) overall performance of the system: retention time reproducibility < 0.008%; Peak area reproducibility < 0.55% RSD; Integral gas passivation. 2. Detector (1) Hydrogen flame detector, with electronic gas circuit control, the maximum operating temperature 450 ° C, the minimum detection limit: < 1.2 pg C/s, the linear dynamic range > 107, and the whole-process digital data path can conduct quantitative analysis of the peak within the whole concentration range of 107 in a single operation. Maximum data collection rate: up to 900 Hz; (2) thermal conductivity detector, with electronic gas circuit control, universal detector, responding to all compounds except the carrier gas, the minimum detection limit: 400 pg/mL, linear dynamic range: > 105±5%, the highest temperature: 400 ° C; (3) flame extinction detection and automatic reignition. 3. Shunt/non-shunt capillary injection port with electronic gas circuit control (1) Electronic pressure/flow control (including carrier gas, fuel gas and auxiliary gas); (2) sealing system of plate-rotating top cover inject port, convenient for maintenance and disassembly; (3) diagnosis including leakage/current limiting, pressure attenuation and current limiting test at the shunt outlet (nut removal pad purge and shunt outlet); (4) the maximum operating temperature: 400 ℃. (5) pressure range: 0-1032kpa; (6) maximum shunt ratio: 7000:1; (7) setting range of total flow: 500ml /min N2 4, Gas injection valve: each one of six-way gas injection valve and ten-way gas injection valve, automatic heating up to 220 ° C. 5. Valve housing: two valves can be installed and automatically controlled in a separate temperature-controlled valve housing, with automatic heating up to 220 degrees 6. Workstation: software: WINDOWS 10 Chinese operating system, Chinese intelligent software and retention time locking software. Chromatographic software with personalized processing for data processing, equipment control, data analysis and automatic control.
3 Gas chromatograph 1 Set 1.Structure (1) 7-inch capacitive touch screen interface provides real-time access to instrument status, configuration, and flow path information. (2) The Browser Interface through the IP address of GC remote control the instruments. The Browser Interface is the most extensive interface to GC's intelligence and mobile access features. (3) It has expanded configuration capabilities, where up to two inlets and four detectors can be installed and operated simultaneously. Six GC column smart keys and three USB ports are provided. (4) System whole performance: Retention time reproducibility:< 0.008% or < 0.0008 min; Peak area reproducibility:< 0.55% RSD; Whole gas circuit passivation. 2.column oven (1) Operating temperature: room temperature 4 ℃ to 450 ℃; (2) Temperature setting accuracy: 0.1 ℃;(3) The maximum heating rate: 100 ℃ / min;(4) Temperature programmed order number: Supports 20 oven ramps with 21 plateaus. Negative ramps are allowed;(5) Ambient rejection: <0.01 °C per 1 °C; (6) Temperature programmed reproducibility: 1% or less. 3.Heating Zone (1) Independent Heating Zone, without Column Temperature Box: 8; (2) Maximum operating temperature of auxiliary heating zone: 400 degree °C; (3) Support up to 10 valves. 4.Electronic Gas Control (1) Modular Electronic Gas Control Channel, including all flow and pressure control of the inlet, detector or auxiliary gas channel, and equipped with anti-particle contamination devices. (2) Pressure setting accuracy: 0.003 PSI, At mospheric pressure sensor compensates for the change of altitude and ambient temperature;(3) Program Boost/Boost: Order 3;(4) has a variety of electronic pneumatic control operation modes: constant current, constant pressure, programmed up-flow, programmed up-pressure, pulse pressure;(5) Flow Sensor Accuracy: <+5% 5. Detector (1)Detector: Four detectors can be installed and operated simultaneously. They are suitable for electronic gas of all detector gases. Circuit control and electronic on/off, electronic gas control can compensate for atmospheric pressure and temperature changes. (2) Flame Ionization Detector with Electronic Air Circuit Control;(3)Maximum operating temperature 450 ℃;(4) Minimum detection limit: < 1.2 PG C/s calculated as n-tridecane;(5)Linear dynamic range > 107, the whole digital data path can run at one time to the whole 107 concentration standard. Quantitative analysis of the periphery peaks was carried out;(6) Maximum data acquisition rate: up to 900 Hz, and provide relevant proof;(7) * Flameout Detection and Automatic Reignition. 6. Split/Splitles capillary inlets with EPC (1) Electronic Pressure/Flow Control (Including Carrier Gas, Gas and Gas Aid; (2) Sample Inlet Sealing System with Turning Top Cover for Easy Maintenance and Disassembly;(3) Diagnosis including leakage/current limiting, pressure attenuation and current limiting test at diversion outlet (removal of nut spacer purge)And diversion outlets);(4) Maximum operating temperature: 400 C;(5) Pressure Range: 0-1032 Kpa;(6) Maximum shunt ratio: 7500:1; (7) Total Flow Setting Range: 500 mL/min N2; 7.Six Ventilator Sampling Valve: Automatic heating up to 220 °C 8.valve box: Installation and automatic control of a valve in a separate temperature control valve box, automatic heating up to 220 ℃ 9.Automatic Sampler:(1)greater than 165 bits;(2) sampling range: 0.1-50ul;(3) Sample Input Linearity: > 99% 10. Workstation Software: WINDOWS 10 Chinese Operating System, Chinese Intelligent Software, with Reserved Time Lock Fixed software. Chromatographic software includes data processing, equipment control, data analysis, automatic control and personalized processing.
4 Gas chromatograph 1 Set 1. Reproducibility of retention time: <0.008% or <0.0008 minutes; reproducibility of peak area: <0.55% RSD; 2. Column box: operating temperature: room temperature +4℃~450℃; temperature setting accuracy: 0.1℃; maximum heating rate: >100 / min; cooling rate is setable; repeatability of temperature programmed: <1%; 3. Flame ionization detector: maximum operating temperature:450℃; minimum detection limit: <1.2 pgC/s, calculated with n-tridecane; linear dynamic range >107; 4. Automatic sampler: >17 bits; sampling range: 0.1-50uL; 6-way gas injection valve with heating function is provided; 5. Vertical vacuum oven: automatic vacuum pumping, 4L vacuum pump (extraction vacuum less than 5 minutes); temperature fluctuation (+5℃); vacuum degree <133 pa; inner liner size: 450 *450 *450 mm; 6. Central cutting technology.

3、Qualification Requirements For Bidder
Qualifications or Performance:Qualification for the bidder:
If the goods originated in PRC, the bidder must be the manufacturer.
If the goods originated outside PRC, the bidder must be the manufacturer.
The bidder shall provide the sales performance of more than 30 sets (including 30 sets) of Gas Chromatograph in domestic scientific research institutes, colleges and universities from 2018 to now, with tabular statement. And the application performance shall include at least 3 (including 3) different users. If necessary, party A will conduct on-spot inspection.
Verification of valid performance documents:
(1) Form of valid supporting documents: copy of valid sales contract or copy of VAT invoice
(2) The contents of valid certification documents shall at least include: type, specification, quantity, user name, sales time, and contact person and contact information.
If there is false information, regardless of any reason, the bidding will be rejected.

Joint Bids:NOT Available
Bid without the bidding documents:NOT Available
4、Acquisition of Bidding Documents
Beginning of Selling Bidding Documents:2019-06-06
Ending of Selling Bidding Documents:2019-06-14
Sell bidding?doc?online?or?not:No
To Obtain:On-line Download,On-site Purchase
Place:jh_zbfs2@petrochina.com.cn
Price of Bidding Documents:¥¥500/$75/$75
5、Bid Submission
Deadline for Submitting Bids/Time of Bid Opening (Beijing Time):2019-07-23 09:00
Place of Bid:No.1 Bidding Room, First Floor of Block D, Jilin Crystal Hotel , 29 Longtan Street ,Jilin City, Jilin, PRC
Place of Bid Opening:No.1 Bidding Room, First Floor of Block D, Jilin Crystal Hotel , 29 Longtan Street ,Jilin City, Jilin, PRC
6、The bidder needs to register before the tender on www.chinabidding.com. And the evaluation results will be released on www.chinabidding.com.
7、Contact Details
Purchasers:PETROCHIAN JILIN CHEMECAL
Add.:/
Contact:/
Tel:/
Bidding Agency:Jilin Chemical Industries Import and Export Company Limited
Add.:Block C, Jilin Crystal Hotel , 29 Longtan Street ,Jilin City, Jilin Prov, P.R.China
Contact:Li Yuan
Tel:0432-63983680
8、Remittance Approach:
Bank(RMB):INDUSTRIAL AND COMMERCIAL BANK OF CHINA, JILINCITY BRANCH
Bank(USD):INDUSTRIAL AND COMMERCIAL BANK OF CHINA, JILINCITY BRANCH
Account NO.(RMB):0802212009200065682
Account NO.(USD):0802212029200008692